Cut P-System grooves into the end faces.
Place the component in the correct position of the counterpart and apply the centre cleft.
Align the Zeta P2 with the centre marking and cut the grooves in the surface.
Insert the connectors halves.
Insert the component into the carcase and swivel in place.
The flexible positioning pins engage in the correct position.
Tighten the Clamex P-14/10 Flexus with the assembly tool.
To disassemble, simply release the lever again.
Move component sideways and remove.